There are 4 main fire protection grades for polyurethane sandwich cold storage panels, and the paint performance requirements are as follows:
1. Grade A: non-flammable, non-combustible, and non-drip.
2. Grade B1: difficult to burn, non-combustible, and non-dripping sparks and molten droplets.
3. Grade B2: poor flammability, self-extinguishing after leaving the fire.
4. Grade B3: flammable material.
The impact of fire protection grade on the performance of cold storage panels
Grade A: has the highest fire protection performance, suitable for cold storage with extremely high fire protection requirements.
Grade B1: difficult to burn, suitable for cold storage with certain fire protection requirements.
Grade B2: flammable but self-extinguishing after leaving the fire, suitable for cold storage with general fire protection requirements.
Grade B3: flammable, currently not recommended for cold storage and most building materials scenarios.
+86 19937800438